-40%

Parker Domnick Hunter ZHFT/AT 539509853 .2μm Filter Element High Flow Tetpor NEW

$ 118.8

Availability: 100 in stock
  • Condition: New
  • All returns accepted: Returns Accepted
  • Type: Filter Element
  • Refund will be given as: Money Back
  • Item must be returned within: 14 Days
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Brand: Parker
  • MPN: 50 442 1110 010

    Description

    Parker Domnick Hunter ZHFT/AT 539509853 .2μm Filter Element High Flow Tetpor II NEW!!  1-Piece (each)
    *******************************************  FREE SHIPPING!!  ****************************************
    New in manufacturers sealed bags, see pictures for actual condition.  Sold as 1-piece (each).
    This is a
    Parker Domnick Hunter™ 125mm HIGH FLOW TETPOR II Air/Gas Filter.  It is rated at 0.2 micron and used for gas sterilization.  The filter is 125mm long (5 inches) and uses a Truseal end cap.  Sold as 1-piece (each).
    This listing is for ONE (1)
    Parker Domnick Hunter ZHFT/AT 539509853 .2μm Filter Element.
    Thanks for looking!!
    From the manufacturer:
    Provide full retention of bacteria, viruses, and particulate in process air and gas streams, with optimum efficiency, flow rate, and strength, and zero fiber shedding
    HIGH FLOW TETPOR II gas sterilization filters have been developed to benefit from technological advances within the manufacture of PTFE membranes. This new generation of filter sets the standard with an unrivalled combination of efficiency, flow rate and strength.
    The HIGH FLOW TETPOR II is validated as a 0.2 micron sterilizing grade filter in liquids through ASTM F838-05 in gas through full retention to an aerosol challenge of MS2 phage. This ensures the filter will guarantee the sterility of your process in the worst-case scenario where the filter may be subjected to bulk liquid due to a process problem. Subtle changes to the structure of the hydrophobic PTFE have also resulted in the production of an extremely robust product now validated for 225 steam sterilization cycles @ 142 °C (287.6 °F). The combination of non-woven supports upstream of the membrane and an expanded net layer downstream has significant benefits. It provides increased protection and service life while guaranteeing zero fibre shedding into the process.
    HIGH FLOW TETPOR II is suitable for all sterile gas applications including fermentation inlet and off gas streams, venting, lyophilisers, autoclave vacuum breaks and blow-fill-seal equipment as well as the provision of particle free air within the electronics industry.
    Features and Benefits
    • Optimum pleat configuration
    • Steam sterilizable up to 225 cycles at 142 °C (287.6 °F)
    • Unrivalled flow rates combined with low pressure drops
    • Fully validated to ASTM 838-05 for liquid bacterial challenge
    • Fully validated to aerosol and viral challenge
    • Integrity testable by all methods including water intrusion test
    Specifications Materials of Construction
    Filtration Membrane: Polytetrafluoroethylene PTFE
    Upstream Support: Polypropylene
    Downstream Support: Polypropylene
    Inner Support Core: 316L Stainless Steel
    Outer Protection Cage: Polypropylene
    End Caps: Polypropylene
    End Cap Insert: Polysulphone
    Standard o-rings: Silicone Food and Biological Safety Materials conform to the relevant requirements of 21CFR Part 177, EC1935 / 2004 and current USP Plastics Class VI - 121 °C and ISO10993 equivalents.
    Recommended Operating Conditions
    The maximum differential pressure in direction of flow (outside to in) is 3.5 barg (50.76 psig) at 60 °C (140 °F). The maximum recommended continuous inlet air temperature is 60 °C (140 °F).
    Note:
    HIGH FLOW TETPOR II cartridges can be used as WFI vents in heated housings if changed on a 4-6 monthly basis. Sterilization HIGH FLOW TETPOR II cartridges can be in situ steam sterilized for up to 225 cycles at 142 °C (287.6 °F).
    Retention Characteristics
    HIGH FLOW TETPOR II cartridges have been fully validated as 0.2 micron sterilizing grade filter cartridges, for compressed air and gas applications. They exceed liquid bacterial challenge levels as recommended by ASTM+. In addition, HIGH FLOW TETPOR II is also validated by aerosol bacterial and MS-2 Coliphage challenge testing. +ASTM American Society for Testing and Materials Integrity Test Data All cartridges are integrity tested prior to despatch by the pressure decay and aerosol challenge test methods. Values are for cartridges wetted with 60 / 40 IPA / Water